Specifications
- Type
- Power triode, air-cooled
- Heater voltage (Vh)
- 10 V
- Heater current (Ih)
- 4.25 A
- Anode dissipation (Pa)
- 90 W
- Output power
- 220 W
- Amplification factor (µ)
- 20
- Cathode type
- FT (thoriated-tungsten filament)
- Overall length
- 190 mm
- Diameter
- 65 mm
- Max. DC anode voltage
- 2250 V
- Max. DC anode input
- 350 W
- Max. frequency at full ratings
- 75 MHz
Description
The 3T12 is a power triode, air-cooled, made by Hitachi (Japan), listed in the „Hitachi Electron Tubes” catalogue (CT-358), section „Power Tubes – Triodes (Air-Cooled)” (pp. 4–5): „Intended for use in industrial heating” [1].
Maximum plate ratings and typical operating conditions, as printed [1]:
| Class | Max. frequency (Mc) | Max. DC plate (V) | Max. DC input (W) | Max. dissipation (W) | DC plate (V) | DC grid (V) | DC plate (A) | Driving power (W) | Power output (W) |
|---|---|---|---|---|---|---|---|---|---|
| CP | 75 | 1,800 | 230 | 60 | 1,500 | -300 | 0.125 | 13 | 145 |
| CP | 75 | 2,250 | 350 | 90 | 2,000 | -250 | 0.15 | 10 | 220 |
Classes of service: CP = Class-C plate-modulated telephone service [2]; Maximum ratings in the Absolute Maximum Rating System, for continuous service unless otherwise noted; in classes CM, CP and CT the values are for one tube (two units in twin-unit types), in classes AB1, AB2 and B the maximum plate ratings are for one tube and the typical operating conditions for two tubes (or two units) [2]; In Specifications the max. anode voltage, input, dissipation, frequency and the output power are the highest values of the table [1].
Drawing Gallery
No image availablePhoto Gallery
No other images available yet.
Documents
No documents available yet.
Prices
N/A
References
- [1]Hitachi, Ltd. – „Hitachi Electron Tubes” (catalogue CT-358), Tokyo (the year is not given), section „Power Tubes – Triodes (Air-Cooled)”, pp. 4–5