General view

CSA 10-220

IPRS Băneasa

Also known as
CSA 10-220 (220V/5A), CSA 10-220R (220V/10A)
Year
Unknown
Category
Industrial Electronics
Type
Power assemblies
Documentation score
1/7
Last edited
30 OCT 2026

Specifications

Type
single-phase A.C. switch / controller
Working voltage
220 V
Working current
5–10 A (see Variants)
Cooling
air
Control signal
switch off = 0 V, switch on = +10 V; the analog signal 0…10 V controls the load power (177…0 electric degrees)
Working frequency
mains frequency only
Working temperature
−25…+40 °C
Storage temperature
−33…+55 °C
Dimensions
88 × 23 × 80 mm
Weight
0.25 kg

Sources: [1]

Variants (2)

NoteCompare
CSA 10-220 (220V/5A)5preliminary data („$”); for inductive loads
CSA 10-220R (220V/10A)10preliminary data („$”); for resistive-inductive loads

Click a column heading to sort. „+” adds a variant to the comparison (CSA 10-220).

Description

The CSA 10-220 is a series of single-phase A.C. switches / controllers made by IPRS Băneasa [1].

The I.P.R.S. Băneasa Full Line Condensed Catalog (1990) lists the CSA 10-220 in 2 versions among its single-phase „A.C. switches / controllers”, the type including the working voltage and current [1]. The versions are for 220 V and 5 and 10 A [1]. The cooling (column „COOLING AGENT ( NOTE 2 )”) is air; the protection column is empty for these rows; the dimensions are 88 × 23 × 80 mm (given as „mm/mm/mm”, without saying which is which) and the weight 0.25 kg [1].

The notes with the table: „$ Preliminary data”; „WARNING : - A.C. switches / controllers MUST be manually trimmed at Load Power Factor ( cos ø ) for inductive loads.”; „CONTROL SIGNAL : - Switch off = 0 V ; - Switch on = +10 V . - The analog signal 0…10 V is used to control the load power ( 177…0 electric degrees ).”; „Types CSA 10-220 / CSA 10-380 are intended to be used for inductive loads ; types CSA 10-220R / CSA 10-380R for resistive - inductive loads.”; „NOTE 1 : Working temperature -25 … +40 oC ( air cooled ) + 5 … +40 oC (liquid cooled) ; Storage temperature : -33 … +55 oC”; „NOTE 2 : Cooling agent : A = air ; L = liquid , minimum 6 l/min.”; „NOTE 3 : PROTECTION TYPE : 1 = over-voltage ; 2 = du/dt ; 3 = thermal ; 4 = over-current”; „NOTE 4 : These switches / controllers are intended to be used for MAINS FREQUENCY only.”; „NOTE 5 : Mains transformers and / or inductances are NOT SUPPLIED by the manufacturer .” [1].

The same table also lists the CSA 10-380, CSMA, CSA 220V(380V) and CSMLD [1].

Schematics

No schematics available yet.

Documents

No documents available yet.

Prices

N/A

References

  1. [1]I.P.R.S. Băneasa – „Full Line Condensed Catalog”, 1990, section 9 „Power assemblies”, single-phase „A.C. switches / controllers”, pp. 9-05…9-06