General view

CSTRF

IPRS Băneasa

Also known as
CSTRF 380V/400A, CSTRF 380V/700A
Year
Unknown
Category
Industrial Electronics
Type
Power assemblies
Documentation score
1/7
Last edited
30 OCT 2026

Specifications

Type
three-phase pulse-train A.C. controller
Working voltage
380 V
Working current
400–700 A (see Variants)
Cooling
natural air, forced air (see Variants)
Protection
over-voltage, du/dt, thermal, short-circuit
Control signal
unified voltage signal 0…10 V or unified current signal 2…10 / 4…20 mA
Working frequency
mains frequency only
Working temperature
−25…+40 °C
Storage temperature
−33…+55 °C
Dimensions
350 × 550 × 540 mm, 350 × 650 × 540 mm (see Variants)
Weight
70–76 kg (see Variants)

Sources: [1]

Variants (2)

Compare
CSTRF 380V/400A400natural air350 × 550 × 540 mm70
CSTRF 380V/700A700forced air350 × 650 × 540 mm76

Click a column heading to sort. „+” adds a variant to the comparison (CSTRF).

Description

The CSTRF is a series of three-phase pulse-train A.C. controllers made by IPRS Băneasa [1].

The I.P.R.S. Băneasa Full Line Condensed Catalog (1990) lists the CSTRF in 2 versions among its three-phase „Pulse-train A.C. controllers”, the type including the working voltage and current [1]. The versions are for 380 V and 400 and 700 A [1]. The cooling (column „AIR COOLING ( NOTE 2 )”) is natural air and forced air; the protection type is „1, 2, 3, 6”; the dimensions are 350 × 550 × 540 mm or 350 × 650 × 540 mm (given as „mm/mm/mm”, without saying which is which) and the weight 70 or 76 kg [1].

The table refers to another page for its notes („IMPORTANT : See page 9 - 11 for NOTES .”); they give: „WARNING : - A.C. switches / controllers MUST be manually trimmed at Load Power Factor ( cos ø ) for inductive loads.”; „CONTROL SIGNAL : - Power control is achieved with an unified voltage signal 0…10 V or an unified current signal 2…10/4…20 mA.”; „NOTE 1 : Working temperature : -25 … +40 oC ; Storage temperature : -33 … +55 oC”; „NOTE 2 : N ( natural ) , F ( forced ) air cooling”; „NOTE 3 : 1 = over-voltage ; 2 = du/dt ; 3 = thermal ; 4 = over-current ; 5 = phase / thyristor open ; 6 = short-circuit .”; „NOTE 4 : These switches are intended to be used for MAINS FREQUENCY only .”; „NOTE 5 : Mains transformers and / or inductances are NOT SUPPLIED by the manufacturer .” [1].

Schematics

No schematics available yet.

Documents

No documents available yet.

Prices

N/A

References

  1. [1]I.P.R.S. Băneasa – „Full Line Condensed Catalog”, 1990, section 9 „Power assemblies”, three-phase „Pulse-train A.C. controllers”, pp. 9-11…9-12