MPT-MV
IPRS Băneasa
- Also known as
- MPT-MV 24V/1350A, MPT-MV 24V/1500A, MPT-MV 220V/520A, MPT-MV 220V/680A, MPT-MV 220V/850A, MPT-MV 660V/850A, MPT-MV 660V/1050A
- Manufacturer
- IPRS Băneasa

- Country
- Romania
- Year
- Unknown
- Category
- Industrial Electronics
- Type
- Power assemblies
- Documentation score
- 1/7
- Last edited
- 30 OCT 2026
Specifications
- Type
- three-phase non-controlled bridge
- Working voltage
- 24–660 V (see Variants)
- Working current
- 520–1500 A (see Variants)
- Cooling
- forced air
- Protection
- short-circuit, over-voltage, du/dt, thermal (PTC thermistors)
- Working frequency
- mains frequency only
- Working temperature
- −25…+40 °C
- Storage temperature
- −33…+55 °C
- Dimensions
- 300 × 650 × 375 mm
- Weight
- 55 kg
Sources: [1]
Variants (7)
| Compare | |||
|---|---|---|---|
| MPT-MV 24V/1350A | 24 | 1350 | |
| MPT-MV 24V/1500A | 24 | 1500 | |
| MPT-MV 220V/520A | 220 | 520 | |
| MPT-MV 220V/680A | 220 | 680 | |
| MPT-MV 220V/850A | 220 | 850 | |
| MPT-MV 660V/850A | 660 | 850 | |
| MPT-MV 660V/1050A | 660 | 1050 |
Click a column heading to sort. „+” adds a variant to the comparison (MPT-MV).
Description
The MPT-MV is a series of three-phase non-controlled bridges made by IPRS Băneasa [1].
The I.P.R.S. Băneasa Full Line Condensed Catalog (1990) lists the MPT-MV in 7 versions among its three-phase „Non controlled bridges”, the type including the working voltage and current [1]. The versions are for 24 to 660 V and 520 to 1500 A [1]. The cooling (column „AIR COOLING ( NOTE 2 )”) is forced air; the protection type is „1, 2, 3, 4”; the dimensions are 300 × 650 × 375 mm (given as „mm/mm/mm”, without saying which is which) and the weight 55 kg [1].
The table refers to another page for its notes („IMPORTANT : See page 9 - 08 for NOTES .”); they give: „NOTE 1 : Working temperature : -25 … +40 oC ; Storage temperature : -33 … +55 oC”; „NOTE 2 : N ( natural ) , F ( forced ) air cooling”; „NOTE 3 : 1 = short-circuit ; 2 = over-voltage ; 3 = du/dt ; 4 = thermal ( with PTC thermistors )”; „NOTE 4 : These switches / controllers are intended to be used for MAINS FREQUENCY only.”; „NOTE 5 : Mains transformers and / or inductances are NOT SUPPLIED by the manufacturer .” [1].
The same table also lists the PT, PTB, MPT-M, MPT and MPT-V [1].
Photo Gallery
No other images available yet.
Schematics
No schematics available yet.
Documents
No documents available yet.
Prices
N/A
References
- [1]I.P.R.S. Băneasa – „Full Line Condensed Catalog”, 1990, section 9 „Power assemblies”, three-phase „Non controlled bridges”, pp. 9-07…9-08