MPTC-V
IPRS Băneasa
- Also known as
- MPTC-V 220V/1050A, MPTC-V 380V/1050A, MPTC-V 525V/1700A, MPTC-V 525V/2000A, MPTC-V 825V/850A, MPTC-V 825V/1350A, MPTC-V 900V/680A, MPTC-V 900V/1200A
- Manufacturer
- IPRS Băneasa

- Country
- Romania
- Year
- Unknown
- Category
- Industrial Electronics
- Type
- Power assemblies
- Documentation score
- 1/7
- Last edited
- 30 OCT 2026
Specifications
- Type
- three-phase fully controlled bridge
- Working voltage
- 220–900 V (see Variants)
- Working current
- 680–2000 A (see Variants)
- Cooling
- forced air
- Protection
- short-circuit, over-voltage, du/dt, thermal (PTC thermistors)
- Working frequency
- mains frequency only
- Working temperature
- −25…+40 °C
- Storage temperature
- −33…+55 °C
- Dimensions
- 536 × 780 × 350 mm
- Weight
- 90 kg
Sources: [1]
Variants (8)
| Compare | |||
|---|---|---|---|
| MPTC-V 220V/1050A | 220 | 1050 | |
| MPTC-V 380V/1050A | 380 | 1050 | |
| MPTC-V 525V/1700A | 525 | 1700 | |
| MPTC-V 525V/2000A | 525 | 2000 | |
| MPTC-V 825V/850A | 825 | 850 | |
| MPTC-V 825V/1350A | 825 | 1350 | |
| MPTC-V 900V/680A | 900 | 680 | |
| MPTC-V 900V/1200A | 900 | 1200 |
Click a column heading to sort. „+” adds a variant to the comparison (MPTC-V).
Description
The MPTC-V is a series of three-phase fully controlled bridges made by IPRS Băneasa [1].
The I.P.R.S. Băneasa Full Line Condensed Catalog (1990) lists the MPTC-V in 8 versions among its three-phase „Fully controlled bridges”, the type including the working voltage and current [1]. The versions are for 220 to 900 V and 680 to 2000 A [1]. The cooling (column „AIR COOLING ( NOTE 2 )”) is forced air; the protection type is „1, 2, 3, 4”; the dimensions are 536 × 780 × 350 mm (given as „mm/mm/mm”, without saying which is which) and the weight 90 kg [1].
The table refers to another page for its notes („IMPORTANT : See page 9 - 10 for NOTES .”); they give: „NOTE 1 : Working temperature : -25 … +40 oC ; Storage temperature : -33 … +55 oC”; „NOTE 2 : N ( natural ) , F ( forced ) air cooling”; „NOTE 3 : 1 = short-circuit ; 2 = over-voltage ; 3 = du/dt ; 4 = thermal ( with PTC thermistors )”; „NOTE 4 : These switches / controllers are intended to be used for MAINS FREQUENCY only.”; „NOTE 5 : Mains transformers and / or inductances are NOT SUPPLIED by the manufacturer .” [1].
The same table also lists the PTC, PTCB, MPTC-M, MPTC-MV and MPTC [1].
Photo Gallery
No other images available yet.
Schematics
No schematics available yet.
Documents
No documents available yet.
Prices
N/A
References
- [1]I.P.R.S. Băneasa – „Full Line Condensed Catalog”, 1990, section 9 „Power assemblies”, three-phase „Fully controlled bridges”, pp. 9-09…9-10