No image availableSpecifications
- Function
- absolute and comparative (−20 … +20 %) measurement of resistance, capacitance and inductance
- Measuring ranges
- R 0.5 Ω – 105 MΩ; L 50 µH – 105 H; C 1 pF – 1050 µF
- Frequency range
- 50 Hz and 1 kHz internal; external up to 10 kHz
- Accuracy
- R ±(1% of reading + 0.25% of full scale) at 100 Ω – 10 MΩ; C and L ±(1.5% + 0.25%)
- Power supply
- 220 V ±10%, 50 Hz
- Power consumption
- max 10 VA
- Dimensions
- 260 × 140 × 250 mm (W × H × D)
- Weight
- 5 kg
Description
The E0704 is an RLC bridge, made by IEMI in Bucharest and designed at the ICE research institute [1].
ICE’s laboratory for electronic instruments for measuring electrical quantities designed all the institute’s generations of oscilloscopes, voltmeters, multimeters, signal generators, frequency meters, logic analysers, RLC bridges and stabilised AC power supplies; they went into production at IEMI or in ICE’s own microproduction workshop, and equipped industrial laboratories and production lines as well as teaching and research laboratories [1]. In the 1970s and 1980s about half of the components of measuring instruments were imported; after 1980 about three quarters were Romanian [1].
IEMI’s production table lists 3,672 units made in 1974–1984 [2].
Its list price, set in 1982, was 12,090 lei [3].
Annex III.2.10 details its ranges: resistance in eight decade ranges (10 Ω – 100 MΩ full scale), measured with internal direct current; capacitance in eight ranges, at 1 kHz up to 1 µF and at 50 Hz above, with an external bias of up to 10 V; inductance in six ranges (1 mH – 100 H) at 1 kHz, with external premagnetisation of up to 10 mA. All three could also be measured by comparison, within ±20% of a reference [4].
The Agenda radioelectronistului (2nd edition, 1989) lists the „E-0704” („Punte RCL”, RCL bridge) among the instruments for measuring the parameters of components and circuits of the E-07 group made by IEMI [5]. Its table gives resistances of 0.5…105·10⁶ Ω (printed „105±10⁶”), capacitances printed „10⁻¹²…1,05·10²” F and inductances of 5·10⁻⁵…105 H, each with an error of at most ±5 %, a 220 V supply, at most 10 VA, 14 × 26 × 25 cm (height × width × depth) and at most 6.5 kg [5].
The IEMI catalogue 1980 presents it as the „E 0704 – R.C.L. bridge”, for absolute or comparative measurements of resistances (0.50 Ω – 105 MΩ), capacitances (1 pF – 1,050 µF) and inductances (50 µH – 105 H), percentage measurements of −20 … +20 %, the null being shown on a meter, in plant and research laboratories and workshops [6].
Its table gives: for resistance, an internal DC voltage, max. 100 mW in the measured element, 0.5 Ω – 105 MΩ in 8 decade ranges (full scales 10 Ω to 100 MΩ), an error of max. ±1 % of reading ±25 % (as printed) of full scale for 100 Ω – 10 MΩ and ±2 % ±0.25 % for 10–100 Ω and 10–100 MΩ, and a comparative range of −20 … +20 % for 10 Ω – 100 MΩ (error max. 2 % for 10 Ω – 10 MΩ, 5 % for 1–100 Ω and 10–100 MΩ); for capacitance, an internal 50/60 Hz or 1 kHz signal or an external one (max. 10 kHz, 2 V rms), a max. external polarisation of 10 V DC, max. 1 V rms across the element, 1 pF – 10 µF in 8 steps (full scales 100 pF – 1 µF at 1 kHz, 10 µF – 1,000 µF at 50 Hz), an error of max. ±1.5 % of reading ±0.25 % of full scale for 100 pF – 100 µF and ±5 % ±0.25 % for 10–100 pF and 100–1,000 µF, a stray capacitance of 10 pF across the terminals, a series-loss compensation of tg = 0…0.6 at 50 Hz (0…0.7 at 60 Hz) and 0…0.25 at 1 kHz, and comparative measurements of −20 … +20 % for 10 pF – 1,000 µF (error max. ±2 % for 100 pF – 1,000 µF); for inductance, an internal 1 kHz signal or an external one (max. 10 kHz, 2 V rms), a max. premagnetisation of 10 mA and 10 V DC, max. 1 V rms across the element, 50 µH – 105 H in 6 steps (full scales 1 mH, 10 mH, 1 H and 100 H as printed), an error of max. ±1.5 % of reading ±0.25 % of full scale for 100 µH – 100 H, a coarse and fine series-loss compensation for Q = 1…50 at 1 kHz, and comparative measurements of −20 … +20 % for 1 mH – 100 H (error max. ±2 %) [6]. It takes max. 10 VA from 220 V ±10 %, 50/60 Hz ±5 %, works at +10 to +35 °C and max. 80 % humidity, and measures 260 × 140 × 250 mm (W × H × D), 6.5 kg [6]. Its weight differs from the 5 kg in the specifications [6].
Photo Gallery
No image availableSchematics
No schematics available yet.
Documents
No documents available yet.
Prices
N/A
References
- [1]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, section II.4.1 „Laborator aparate electronice pentru măsurarea mărimilor electrice”, pp. 109–115
- [2]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, sections III.2 „Producția IEMI” and III.3 „Comentarii tehnico-economice”, pp. 302–317, and annex III.2.3 „Producția IEMI – aparate electronice de măsură și industriale”, pp. 383–386
- [3]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, annex III.2.5 „Lista cu prețurile produselor – IEMI”, pp. 393–396
- [4]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, annex III.2.10 „Aparate pentru măsurarea parametrilor componentelor și circuitelor”, pp. 634–646
- [5]N. Drăgulănescu – „Agenda radioelectronistului”, 2nd edition, Editura Tehnică, 1989, section 50.5 „Aparate pentru măsurarea parametrilor componentelor/circuitelor” (producător: IEMI – București), pp. 718–721
- [6]Measuring Electronic Instruments Enterprise (I.E.M.I.), Bucharest – „catalogue 1980” (in English), section II „Electronic instruments for electric quantities measurement”, „E 0704 – R.C.L. bridge” (unnumbered pages)