Specifications

Function
DC voltage
Measuring ranges
0.2 / 2 / 20 / 200 / 1000 V
Accuracy
±(0.15% of reading + 0.05% of full scale)
Input impedance
0.1 MΩ (0.2 V), 1 MΩ (2 V), 10 MΩ (higher ranges)
Display
4½ digits, seven-segment, telephone lamps
Outputs / interface
BCD, for a digital printer
Construction
transistors
Power supply
220 V ±10%
Power consumption
70 VA
Dimensions
20 × 43 × 37 cm (H × W × D)
Weight
20 kg

Sources: [2][3]

Description

The E0301 is a digital voltmeter, made by IEMI in Bucharest and designed at the ICE research institute [1].

ICE’s laboratory for electronic instruments for measuring electrical quantities designed all the institute’s generations of oscilloscopes, voltmeters, multimeters, signal generators, frequency meters, logic analysers, RLC bridges and stabilised AC power supplies; they went into production at IEMI or in ICE’s own microproduction workshop, and equipped industrial laboratories and production lines as well as teaching and research laboratories [1]. In the 1970s and 1980s about half of the components of measuring instruments were imported; after 1980 about three quarters were Romanian [1].

It measures DC voltage [2].

Annex III.2.8 says it measured DC voltages from 100 µV to 1000 V with automatic polarity indication, by successive approximation; with suitable transducers it could also measure non-electrical quantities such as temperature, pressure, dimensions or gas concentrations, and its results could be recorded in binary-coded decimal on a digital printer. It was fully transistorised, with a seven-segment display made of telephone lamps [3].

The Agenda radioelectronistului (2nd edition, 1989) lists the „E-0301” („Voltmetru numeric (4 1/2 cifre)”, digital voltmeter with 4½ digits) among the digital voltmeters and multimeters of the E-03 group made by IEMI; the notes to its entry give a display of luminous segments lit by telephone-type incandescent lamps [4]. Its table gives DC voltages of 10⁻⁴…10 V (±0.2 % of reading, ±0.5 % of full scale), an input resistance of 10…0.1 MΩ (as printed), a 220 V supply, a consumption of at most 70 VA, 20 × 44 × 37 cm (height × width × depth) and at most 21 kg [4]. In the table, „ct” means reading („citire”) and „c.s.” full scale („cap de scară”) [4].

Schematics

No schematics available yet.

Documents

No documents available yet.

Prices

N/A

References

  1. [1]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, section II.4.1 „Laborator aparate electronice pentru măsurarea mărimilor electrice”, pp. 109–115
  2. [2]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, sections III.2 „Producția IEMI” and III.3 „Comentarii tehnico-economice”, pp. 302–317, and annex III.2.3 „Producția IEMI – aparate electronice de măsură și industriale”, pp. 383–386
  3. [3]N. Millea (coord.) et al. – „Electronica românească. O istorie trăită”, vol. II „Electronica profesională”, AGIR, annex III.2.8 „Voltmetre – multimetre – wattmetre”, pp. 618–627
  4. [4]N. Drăgulănescu – „Agenda radioelectronistului”, 2nd edition, Editura Tehnică, 1989, section 50.3 „Voltmetre/multimetre numerice/analogice” (producător: IEMI – București), part B „Voltmetre/multimetre numerice (grupa E-03)”, pp. 711–713